Poloxamer 407

Poloxamer 407 has approximate block lengths of a = 101 and b = 56.

Poloxamer 407 is a hydrophilic non-ionic surfactant of the more general class of copolymers known as poloxamers. Poloxamer 407 is a triblock copolymer consisting of a central hydrophobic block of polypropylene glycol flanked by two hydrophilic blocks of polyethylene glycol. The approximate lengths of the two PEG blocks is 101 repeat units while the approximate length of the propylene gycol block is 56 repeat units.[1] This particular compound is also known by the BASF trade name Pluronic F127 or by the Croda trade name Synperonic PE/F 127.

Uses

Most of the common uses of poloxamer 407 are related to its surfactant properties. For example, it is widely used in cosmetics for dissolving oily ingredients in water. It can also be found in multi-purpose contact lens cleaning solutions, where its purpose there is to help remove lipid films from the lens. It can also be found in some mouthwashes. There is a research ongoing for using poloxamer 407 for aligning severed blood vessels before gluing them surgically.[2]

Reports of adverse effects

It was reported in The Australian newspaper 18 November 2006 that this common ingredient in toothpaste and mouthwash can cause high cholesterol in mice.[3] A team from the Centre for Ageing and the ANZAC Research Institute in Sydney used it as a tool to demonstrate that cells in the liver behave like a sieve. They gave a high dose (1 gram per kilogram of body weight) of Poloxamer 407 to mice which blocked 80% of the pores in liver cells that absorb lipoproteins, leading to a 10-fold increase in plasma lipid levels.[4] However, the dose used is much higher than a person would be exposed to in toothpaste or mouthwash.

Potential degradation by sonication

Wang et al.[5] reported that aqueous solutions of poloxamer 188 (Pluronic® F-68) and poloxamer 407 (Pluronic® F-127) sonicated in the presence or absence of multi-walled carbon nanotubes (MWNTs) can become highly toxic to cultured cells. Moreover, toxicity correlated with the sonolytic degradation of the polymers.

References

  1. Tania Betancourt; The University of Texas at Austin. Biomedical Engineering (2007). Targetable biodegradable nanoparticles for delivery of chemotherapeutic and imaging agents to ovarian cancer. ProQuest. pp. 130–. ISBN 978-0-549-34761-3. Retrieved 16 August 2011.
  2. Stanford University Medical Center (28 August 2011). "Sutureless method for joining blood vessels invented". ScienceDaily.
  3. O'Neill, Craig (18 November 2006). "Dental hygiene gives you a brush with cholesterol". The Australian.
  4. Cogger, VC; Hilmer, SN, Sullivan, D, Muller, M, Fraser, R, Le Couteur, DG (December 2006). "Hyperlipidemia and surfactants: the liver sieve is a link.". Atherosclerosis. 189 (2): 273–81. doi:10.1016/j.atherosclerosis.2005.12.025. PMID 16458315. Cite uses deprecated parameter |coauthors= (help)
  5. Wang, Ruhung; Hughes, Tyler; Beck, Simon; Vakil, Samee; Li, Synyoung; Pantano, Paul; Draper, Rockford K. (2013). "Generation of toxic degradation products by sonication of Pluronic® dispersants: implications for nanotoxicity testing". Nanotoxicology. 7 (7): 1272–1281. doi:10.3109/17435390.2012.736547. ISSN 1743-5390.

External links

This article is issued from Wikipedia - version of the 11/3/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.