Percutaneous transtracheal ventilation

Percutaneous transtracheal ventilation is the delivery of oxygen to the lungs through an over-the-needle catheter inserted through the skin into the trachea using a high pressure gas source is considered a form of conventional ventilation.[1][2][3]

Percutaneous transtracheal ventilation may be mistaken for transtracheal jet ventilation, which is not considered conventional ventilation and refers to high-frequency ventilation; a low tidal volume ventilation and needs specialized ventilators only available in critical care units.

References

  1. Ihra G, Gockner G, Kashanipour A, Aloy A (2000). "High-frequency jet ventilation in European and North American institutions: developments and clinical practice.". Eur J Anaesthesiol. 17 (7): 418–30. PMID 10964143.
  2. Cook TM, Nolan JP, Magee PT, Cranshaw JH (2007). "Needle cricothyroidotomy.". Anaesthesia. 62 (3): 289–90; author reply 290–1. doi:10.1111/j.1365-2044.2007.05004_1.x. PMID 17300309.
  3. Mace SE, Khan N (2008). "Needle cricothyrotomy.". Emerg Med Clin North Am. 26 (4): 1085–101, xi. doi:10.1016/j.emc.2008.09.004. PMID 19059102.
This article is issued from Wikipedia - version of the 5/27/2016. The text is available under the Creative Commons Attribution/Share Alike but additional terms may apply for the media files.